Xi'an TianRui Petroleum Machinery Equipment Co., Ltd.

Xi'an TianRui Petroleum Machinery Equipment Co., Ltd. Providing Cost-Effective Solids Control Solutions

Manufacturer from China
Verified Supplier
8 Years
Home / Products / Drilling Fluid Testing Equipment /

Dzl2003 Electrical Resistivity Meter 10 - 50℃ Working Environment Temperature

Contact Now
Xi'an TianRui Petroleum Machinery Equipment Co., Ltd.
Visit Website
Country/Region:china
Contact Person:MsSunny Lee
Contact Now

Dzl2003 Electrical Resistivity Meter 10 - 50℃ Working Environment Temperature

Ask Latest Price
Video Channel
Model Number :DZL2003
Place of Origin :Xi'an,China
Brand Name :TR Solids Control
Certification :ISO
MOQ :1 pc
Price :Negotiable
Packaging Details :Pallet or wooden case
Delivery Time :Within 15 days after deposit
Payment Terms :L/C, D/A, D/P, T/T, Western Union
Supply Ability :100 pcs per month
Model :DZL2003
Power supply :AC220V±10%;50±1 Hz
Continuous working time with rechargeable cell :30 hours
Working environment temperature :10~50(℃)
Measuring range :0.2~100(Ω·m)
Measuring uncertainty :2.0~5.0(Ω·m)variable range in ±3% Others in ±5%
Measuring temperature range :10~50(℃)with precision range in ±1℃
Setting of standard temperature :15~35(℃) with step is 1℃
Compensation of auto-temperature :-10~10(℃)with step is 0.1℃
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

DZL2003 Resistivity Measuring Meter

1.Summary

The Model DZL2003 resistivity measuring meter of drilling fluids is the newly developed instrument. It is mainly used to measure resistivity or conductivity of various fluids. It can also be applied to measure resisitivity of oil field drilling fluids and various liquids in other industries, and analyze liquid mineralization or provide reference for distinguishing water purity. The instrument is ideal liquid resistivity measuring apparatus and can be widely used to such departments as petroleum, geology, drilling team and laboratory.

Function

1) measuring liquid resistivity

2) measuring liquid temperature

3) automatic exchange of resistivity in standard temperature

4) setting of standard temperature

5) auto-compensation of temperature

6) self-check of measuring apparatus

7) with rechargeable cell set

2. Model DZL2003

3. The main technical parameters of apparatus

Sequence number Name Technical Parameters
1 Power supply AC220V±10%50±1 Hz
2 Continuous working time with rechargeable cell 30 hours
3 Working environment temperature 10~50(℃)
4 Measuring range 0.2~100(Ω·m)
5 Measuring uncertainty

2.0~5.0(Ω·m)variable range in ±3%

Others in ±5%

6 Measuring temperature range 10~50(℃)with precision range in ±1℃
7 Setting of standard temperature 15~35(℃) with step is 1℃
8 Compensation of auto-temperature -10~10(℃)with step is 0.1℃

Dzl2003 Electrical Resistivity Meter 10 - 50℃ Working Environment Temperature

Inquiry Cart 0